Sovra Recon·Vulnerability

CVE-2026-58115

At a glance

CVE-2026-58115 is a critical-severity vulnerability (CVSS score 10.0). CISA has not reported it as exploited to date.

A vulnerability has been identified in SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Advanced (6ES7647-0BA00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 Basic (6ES7647-0BA00-0YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 M.2 (6ES7647-0BB00-1YA2) (All versions running Example Image versions with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions < V4.3.4-1 running Industrial OS with Node-RED installed), SIMATIC IoT2050 SM (6ES7647-0CA00-1AA2) (All versions running Example Image versions with Node-RED installed). Affected devices do not enforce authentication on the Node-RED HTTP interface, allowing unauthenticated access to programming nodes that are capable of executing system commands on the server. This could allow an unauthenticated remote attacker to create malicious flows through the HTTP interface in order to execute arbitrary code on the underlying server with maximum privileges.

Details

The vulnerability in detail

CVE ID
CVE-2026-58115
Severity (CVSS)
Critical · 10.0 / 10
Published
August 11, 2026
Actively exploited
Not reported by CISA to date
CERT-FR advisory (in French)
CERTFR-2026-AVI-1009

What to do

How to protect against CVE-2026-58115

  • Check whether you are affected: identify the installed versions of the product and compare them with the vendor's security advisory.
  • Apply the vendor's patch as a priority on Internet-facing systems.
  • If no patch is available, apply the published workarounds or take the service off the Internet.

Security news

In the news

  • November 3, 2026Exploitation active d'une faille critique CVE-2026-58115 dans les appareils Siemens SIMATIC IoT2050 AdvancedThe Hacker News ↗

Sources

Official descriptions from NVD and CISA, in their original wording.

Patching a CVE is not enough.

The vulnerabilities specific to your application have no CVE. Our AI agents hunt for them by actually attacking your systems.